Required Fields *
In stock
The AFHST-CA-8 is an 8-inch chimney cap from AllFuel HST, constructed from stainless steel. It protects chimney systems from debris and weather and includes a spark screen.
The 8" inner diameter x 36" Long double wall chimney pipe length is used to add length to your chimney stack and includes 1 Locking Band.
The 8" inner diameter x 18" Long double wall chimney pipe length is used to add length to your chimney stack and includes 1 Locking Band.
The 15 Degree Elbow Kit for 8" inner diameter chimney pipe is used to get past rafters or away from an obstruction like plumbing, HVAC, or the roof peak. Up to two lengths of chimney pipe (for a maximum run of 72" between elbows) can be added between elbows to allow for necessary spacing.
An Elbow Strap is included and helps support the weight of the offset from the elbows. If your installation includes two lengths of pipe between the elbows a second Elbow Strap (sold separately) is required.
Our double wall Class-A insulated chimney system delivers superior safety and performance. The 1.18" thick high density ceramic fiber blanket insulation is sandwiched between two 0.019" thick 304 stainless steel walls. Compared to our competitors 430 stainless steel or galvanized steel, 304 stainless steel provides superior corrosion resistance while our 0.019" thick inner and outer walls are as must as 25% thicker than our competition.
Certified and listed to the UL 103HT standard and designed for appliances that are listed for use with a 2100 Degree Fahrenheit High Temperature chimney system. It can be used with wood stoves, fireplaces, fireboxes, furnaces, boilers, water heaters, pizza ovens and other residential heating appliances fueled by wood, gas, coal or oil.
Note: Do not use with forced draft, positive-pressure appliances.
The UL 103HT chimney is designed and tested for maximum continuous use at 1000 degrees Fahrenheit. UL certification requires a stringent and rigorous test including a one hour burn at 1400 degrees Fahrenheit and three - ten minute burns at 2100 degrees Fahrenheit.
Always keep at least a 2-inch clearance between chimney pipe and any combustible materials.
The 30 Degree Elbow Kit is used to get past rafters or away from an obstruction like plumbing, HVAC, or the roof peak. Up to two lengths of chimney pipe (for a maximum run of 72" between elbows) can be added between elbows to allow for necessary spacing.
An Elbow Strap is included and helps support the weight of the offset from the elbows. If your installation includes two lengths of pipe between the elbows a second Elbow Strap (sold separately) is required.
Our double wall Class-A insulated chimney system delivers superior safety and performance. The 1.18" thick high density ceramic fiber blanket insulation is sandwiched between two 0.019" thick 304 stainless steel walls. Compared to our competitors 430 stainless steel or galvanized steel, 304 stainless steel provides superior corrosion resistance while our 0.019" thick inner and outer walls are as must as 25% thicker than our competition.
Certified and listed to the UL 103HT standard and designed for appliances that are listed for use with a 2100 Degree Fahrenheit High Temperature chimney system. It can be used with wood stoves, fireplaces, fireboxes, furnaces, boilers, water heaters, pizza ovens and other residential heating appliances fueled by wood, gas, coal or oil.
Note: Do not use with forced draft, positive-pressure appliances.
The UL 103HT chimney is designed and tested for maximum continuous use at 1000 degrees Fahrenheit. UL certification requires a stringent and rigorous test including a one hour burn at 1400 degrees Fahrenheit and three - ten minute burns at 2100 degrees Fahrenheit.
Always keep at least a 2-inch clearance between chimney pipe and any combustible materials.
The firestop radiation shield is used when passing through a second story floor, and at every floor above, to protect the floor joists where the chimney passes through the floor.
The firestop radiation shield is installed on the underside of the ceiling/floor framing, with the cylindrical "tube" pointing upward.
Example: in a 3 story home where the appliance is on the ground floor the support box is installed in the 1st floor ceiling, a radiation shield is installed at the 2nd and 3rd floor ceilings (where the chimney enters the attic space).
A firestop radiation shield is not installed where the chimney penetrates the roof.
The 36" Square Ceiling Support Box provides safe passage of double wall chimney pipe through your floor or ceiling and supports the weight of the chimney in through the ceiling installations.
The Ceiling Support Box can support a maximum of 50-ft of chimney pipe and includes trim to provide a finished look inside the room. The support box and trim is painted black to match the black single wall stove pipe.
Attached to the bottom of the ceiling support box is a twist lock connection for the Stove Pipe Adapter to connect (sold separately). The support box and trim is painted black.
The adapter section of our Ceiling Support Box's are made of 304 stainless steel while the box itself is made of galvanized steel (as it is not exposed to any corrosive elements).
Certified and listed to the UL 103HT standard and designed for appliances that are listed for use with a 2100 Degree Fahrenheit High Temperature chimney system. It can be used with wood stoves, fireplaces, fireboxes, furnaces, boilers, water heaters, pizza ovens and other residential heating appliances fueled by wood, gas, coal or oil.
Note: Do not use with forced draft, positive-pressure appliances.
The UL 103HT chimney is designed and tested for maximum continuous use at 1000 degrees Fahrenheit. UL certification requires a stringent and rigorous test including a one hour burn at 1400 degrees Fahrenheit and three - ten minute burns at 2100 degrees Fahrenheit.
Always keep at least a 2-inch clearance between chimney pipe and any combustible materials.
The 7/12-12/12 roof flashing provides leak proof penetration of the roof.
Our flashings can be used in both vented and fully sealed applications (including sealed chase installations).
A Storm Collar, sold separately, is required to seal the flashing.
The flat roof flashing provides leak proof penetration of the roof.
Our flashings can be used in both vented and fully sealed applications (including sealed chase installations).
A Storm Collar, sold separately, is required to seal the flashing.
The roof support bracket is used for A-frame and cathedral ceiling homes where a Ceiling Support Box is not desired or required.
The roof support mounts to the framing and can support a total of 45 feet of chimney with a maximum of 20 feet below the support.
An Extended Roof Brace (sold separately) is often used in conjunction with a Roof Support to provide lateral stability above the roof.
The 8" inner diameter x 9" Long double wall chimney pipe length is used to add length to your chimney stack and includes 1 Locking Band.
The 8" inner diameter x 24" Long double wall chimney pipe length is used to add length to your chimney stack and includes 1 Locking Band.
The 8" inner diameter x 48" Long double wall chimney pipe length is used to add length to your chimney stack and includes 1 Locking Band.
The 11" Square Ceiling Support Box provides safe passage of double wall chimney pipe through your floor or ceiling and supports the weight of the chimney in through the ceiling installations.
The Ceiling Support Box can support a maximum of 50-ft of chimney pipe and includes trim to provide a finished look inside the room. The support box and trim is painted black to match the black single wall stove pipe.
Attached to the bottom of the ceiling support box is a twist lock connection for the Stove Pipe Adapter to connect (sold separately). The support box and trim is painted black.
The adapter section of our Ceiling Support Box's are made of 304 stainless steel while the box itself is made of galvanized steel (as it is not exposed to any corrosive elements).
Certified and listed to the UL 103HT standard and designed for appliances that are listed for use with a 2100 Degree Fahrenheit High Temperature chimney system. It can be used with wood stoves, fireplaces, fireboxes, furnaces, boilers, water heaters, pizza ovens and other residential heating appliances fueled by wood, gas, coal or oil.
Note: Do not use with forced draft, positive-pressure appliances.
The UL 103HT chimney is designed and tested for maximum continuous use at 1000 degrees Fahrenheit. UL certification requires a stringent and rigorous test including a one hour burn at 1400 degrees Fahrenheit and three - ten minute burns at 2100 degrees Fahrenheit.
Always keep at least a 2-inch clearance between chimney pipe and any combustible materials.
The 1/12-6/12 roof flashing provides leak proof penetration of the roof. Our flashings can be used in both vented and fully sealed applications (including sealed chase installations).
A Storm Collar, sold separately, is required to seal the flashing.
Our roof flashings are made of 304 stainless steel to deliver superior safety and performance.
Certified and listed to the UL 103HT standard and designed for appliances that are listed for use with a 2100 Degree Fahrenheit High Temperature chimney system. It can be used with wood stoves, fireplaces, fireboxes, furnaces, boilers, water heaters, pizza ovens and other residential heating appliances fueled by wood, gas, coal or oil.
Note: Do not use with forced draft, positive-pressure appliances.
The UL 103HT chimney is designed and tested for maximum continuous use at 1000 degrees Fahrenheit. UL certification requires a stringent and rigorous test including a one hour burn at 1400 degrees Fahrenheit and three - ten minute burns at 2100 degrees Fahrenheit.
Always keep at least a 2-inch clearance between chimney pipe and any combustible materials.
The rain cap with spark arrester tops off the chimney system to retain sparks and hot embers from escaping the chimney as well as to keep rain and snow, debris, and animals from getting inside the chimney.
Our chimney cap uses the same twist lock connection as the rest of our products to allow easy removal for cleaning. The spark guard mesh measures 3/4" to block hot embers from escaping but not being so small that it will clog up from creosote and ash.
Note: 3/4" mesh is not approved for use in California which requires 5/8" mesh.
The storm collar works together with the Roof Flashing to provide a waterproof seal where the chimney passes through the roof.
The storm collar is installed directly above the flashing and must be sealed to the chimney pipe using high-temperature silicone sealant (RTV 500F or better), sold separately.
The attic insulation shield is used in through the ceiling installations to prevent insulation and other debris from contacting the chimney in the attic.
The attic insulation shield is placed above the Ceiling Support Box on top of the framing of the ceiling where the chimney passes through the attic. If the chimney is fully enclosed in a chase the attic insulation shield is not required. Includes 1 Storm Collar.